Difference between cofferdams and caissons
Cofferdams and caissons are both structures that are used when undertaking construction works in areas submerged in under water.
The main difference between the two is that a cofferdam is a temporary structure which is removed after completion of the work, whereas a caisson is built to remain in place as part of the completed structure.
The aim of a cofferdam is to be as watertight as possible to create a dry area in which to carry out the required works, or at least to limit water ingress to a safe level that can be pumped away.
A caisson is typically a box-like structure made of materials such as timber, steel, masonry and reinforced concrete. It may be constructed onshore then floated to the required location, where it is sunk into place, enabling access to the bed to undertake works.
The type of structure being built will determine whether a caisson or a cofferdam is most suitable. The two principal factors influencing the choice are the ground conditions and the depth to which the work is to be taken. In general, cofferdams are suitable for depths of up to 18 m below high water level, while caissons are more suitable for greater depths.
[edit] Related articles on Designing Buildings Wiki
Featured articles and news
There are plenty of sources with the potential to be redeveloped.
Change of use legislation breaths new life into buildings
A run down on Class MA of the General Permitted Development Order.
Solar generation in the historic environment
Success requires understanding each site in detail.
Level 6 Design, Construction and Management BSc
CIOB launches first-ever degree programme to develop the next generation of construction leaders.
Open for business as of April, with its 2026 prospectus and new pipeline of housing schemes.
The operational value of workforce health
Keeping projects moving. Incorporating unplanned absence and the importance of health, in operations.
A carbon case for indigenous slate
UK slate can offer clear embodied carbon advantages.
Costs and insolvencies mount for SMEs, despite growth
Construction sector under insolvency and wage bill pressure in part linked to National Insurance, says report.
The place for vitrified clay pipes in modern infrastructure
Why vitrified clay pipes are reclaiming their role in built projects.
Research by construction PR consultancy LMC published.
Roles and responsibilities of domestic clients
ACA Safety in Construction guide for domestic clients.
Fire door compliance in UK commercial buildings
Architect and manufacturer gives their low down.